        1A097 Human AOPP

        2013年10月10日 15:53:49人氣:224來源:上海蔚霆生物科技有限公司

        資料類型doc文件資料大小428544
        下載次數23資料圖片 【點擊查看】
        上 傳 人上海蔚霆生物科技有限公司 需要積分0
        關 鍵 詞1A097 ,Human ,AOPP
        【資料簡介】

                                  

                      

        ELISA                                  

         

        Human AOPP

        Catalogue Number 1A097

         

         

         

        For the quantitative determination of Human advanced oxidation protein products concentrations in serum- body fluid - celiac fluid - tissue homogenate - culture fluid.

         

         

         

         

        This package insert must be read in its entirety before using this product.

         

         

         

         

        FOR RESEARCH USE ONLY.

        NOT FOR USE IN DIAGNOSTIC PROCEDURES.   

                  http://www.rapidbio.org   

        INTENDED USE AND TEST PRINCIPLE

        This immunoassay kit allows for the quantitative determination of Human AOPP concentrations in serum, plasma, cell culture supernates and other biological fluids.

        Add AOPP to pre-coated AOPP monoclonal antibody microelisa well, incubation; washing. Add HRP tagged AOPP antibodies. After another incubation and washing, remove the unbound enzyme, add Chromogen Solution A and B, the color of the liquid change into blue, and the color finally become yellow at the effect of acid. The depth of the color is positively correlated with concentration of the Human AOPP in samples.

         

        MATERIALS REQUIRED BUT NOT SUPPLIED

        1. 37 ℃ incubator

        2. Standard microplate reader capable of measuring absorbance at 450 nm

        3. Precision pipettes, disposable pipette tips and Absorbent paper

        4. Distilled or deionized water

         

        SAMPLE COLLECTION AND STORAGES

        Serum - Use a serum separator tube and allow samples to clot for 30 minutes before centrifugation for 20 minutes at approximay 1000×g. Remove serum and assay immediay or aliquot and store samples at -20℃ or -80℃.Avoid repeated freeze-thaw cycles

        Plasma - Collect plasma using EDTA or heparin as an anticoagulant. Centrifuge samples for 15 minutes at 1000×g at 2-8℃ within 30 minutes of collection. Store samples at -20℃or -80℃. Avoid repeated freeze-thaw cycles.

        Cell culture supernates and other biological fluids - Remove particulates by centrifugation and assay immediay or aliquot and store samples at -20℃or -80℃. Avoid repeated freeze-thaw cycles.

        Note:  The samples shoule be centrifugated dequay and no hemolysis or granule was allowed.

         

        REAGENTS PROVIDED

        Reagent

         

        Storage

        MICROTITER PLATE

        96 wells

        2-8℃

        STANDARD.I

         0 pmol/L  0.5 ml

        2-8℃ (-20℃)

        STANDARD.II

        50 pmol/L  0.5 ml

        2-8℃ (-20℃)

        STANDARD.III

        100 pmol/L 0.5 ml

        2-8℃ (-20℃)

        STANDARD.IV

        200 pmol/L 0.5 ml

        2-8℃ (-20℃)

        STANDARD.V

        400 pmol/L 0.5 ml

        2-8℃ (-20℃)

        STANDARD.VI

        800 pmol/L 0.5 ml

        2-8℃ (-20℃)

         ENZYME CONJUGATE

        10 ml  1 vial

        2-8℃

        SUBSTRATE A

        6.0 ml  1 vial

        2-8℃

        SUBSTRATE B

        6.0 ml  1 vial

        2-8℃

        STOP SOLUTION

        6.0 ml  1 vial

        2-8℃

        WASH SOLUTION x100

        10 ml  1 vial

        2-8℃

        Closure plate membrane

        2 strips

        -

         

        PRECAUTIONS

        1. Do not substitute reagents from one kit lot to another. Standard, conjugate and microtiter plates are matched for optimal performance. Use only the reagents supplied by manufacturer.
        2. Allow kit reagents and materials to reach room temperature (20-25°C) before use. Do not use water baths to thaw samples or reagents.
        3. Do not use kit components beyond their expiration date.
        4. Use only deionized or distilled water to dilute reagents.
        5. Do not remove microtiter plate from the storage bag until needed. Unused strips should be stored at 2-8°C in their pouch with the desiccant provided.
        6. Use fresh disposable pipette tips for each transfer to avoid contamination.
        7. Do not mix acid and sodium hypochlorite solutions.
        8. Serum and plasma should be handled as potentially hazardous and capable of transmitting disease. Disposable gloves must be worn during the assay procedure, since no known test method can offer complete assurance that products derived from Human blood will not transmit infectious agents. Therefore, all blood derivatives should be considered potentially infectious and good laboratory practices should be followed.
        9. All samples should be disposed of in a manner that will inactivate viruses.
        10. Liquid Waste: Add sodium hypochlorite to a final concentration of 1.0%. The waste should be allowed to stand for a minimum of 30 minutes to inactivate the viruses before disposal.
        11. Substrate Solution is easily contaminated. If bluish prior to use, do not use.
        12. Substrate B contaFE 20% acetone, keep this reagent away from sources of heat or flame.
        13. Remove all kit reagents from refrigerator and allow them to reach room temperature ( 20-25°C).

         

        ASSAY PROCEDURE

        1. Prepare all Standards before starting assay procedure (see Preparation Reagents). It is recommended that all Standards and Samples be added in duplicate to the Microtiter Plate.
        2. First, secure the desired number of coated wells in the holder, then add 50 μL of Standards or Samples to the appropriate well of the antibody pre-coated Microtiter Plate.
        3. Add 100 μL of Enzyme Conjugate to each well. Mix well. Complete mixing in this step is important. Cover and incubate for 1 hour at 37°C.
        4. Prepare Substrate Solution no more than 15 minutes before end of incubation (see Preparation of Reagents).
        5. Wash the Microtiter Plate using one of the specified methods indicated below:
        6. Manual Washing: Remove incubation mixture by aspirating contents of the plate into a sink or proper waste container. Using a squirt bottle, fill each well compley with distilled or de-ionized water, then aspirate contents of the plate into a sink or proper waste container. Repeat this procedure four more times for a total of FIVE washes. After final wash, invert plate, and blot dry by hitting plate onto absorbent paper or paper towels until no moisture appears. Note: Hold the sides of the plate frame firmly hen washing the plate to assure that all strips remain securely in frame.
        7. Automated Washing: Aspirate all wells, then wash plate FIVE times using distilled or de-ionized water. Always adjust your washer to aspirate as much liquid as possible and set fill volume at 350 μL/well/wash (range: 350-400 μL). After final wash, invert plate, and blot dry by hitting plate onto absorbent paper or paper towels until no moisture appears. It is recommended that the washer be set for a soaking time of 10 seconds or shaking time of 5 seconds between washes.
        8. Add 50 μL Substrate A&B to each well. Cover and incubate for 15 minutes at 20-25°C.
        9. Add 50 μL of Stop Solution to each well. Mix well.
        10. Read the Optical Density (O.D.) at 450 nm using a microtiter plate reader within 30 minutes.

         

         

        CALCULATION OF RESULTS

        1. This standard curve is used to determine the amount in an unknown sample. The standard curve is generated by plotting the average O.D. (450 nm) obtained for each of the six standard concentrations on the vertical (Y) axis versus the corresponding concentration on the horizontal (X) axis.
        2. First, calculate the mean O.D. value for each standard and sample. All O.D. values, are subtracted by the mean value of the zero standard before result interpretation. Construct the standard curve using graph paper or statistical software.
        3. To determine the amount in each sample, first locate the O.D. value on the Y-axis and extend a horizontal line to the standard curve. At the point of intersection, draw a vertical line to the X-axis and read the corresponding concentration.
        4. Any variation in operator, pipetting and washing technique, incubation time or temperature, and kit age can cause variation in result. Each user should obtain their own standard curve.
        5. The sensitivity by this assay is 10 pmol/L.
        6. Standard curve

         

         

        上海逸晗生物科技有限公司代理不同品牌價格檔次的ELISA試劑盒。抗體產品等, 品種多,質量好,價格實惠,并且還提供免費代檢測服務。
        本公司的更多產品,請點擊公司:http://www.yihanbio.com/

         

         

         

         

        上海蔚霆生物科技有限公司作者

        上一篇:旋流除油器說明書

        下一篇:全自動臥式打包機樣冊


        我要投稿
        • 投稿請發送郵件至:(郵件標題請備注“投稿”)hbzhan@vip.qq.com
        • 聯系電話0571-87759680
        環保行業“互聯網+”服務平臺
        環保在線APP

        功能豐富 實時交流

        環保在線小程序

        訂閱獲取更多服務

        微信公眾號

        關注我們

        抖音

        環保在線網

        抖音號:hbzhan

        打開抖音 搜索頁掃一掃

        視頻號

        環保在線

        公眾號:環保在線

        打開微信掃碼關注視頻號

        快手

        環保在線

        快手ID:2537047074

        打開快手 掃一掃關注
        意見反饋
        主站蜘蛛池模板: 亚洲成色精品一二三区| 中文字幕av国产精品| 国内极度色诱视频网站| 中文字幕乱码一区二区免费| 女性高爱潮视频| 九九在线精品国产| 久久亚洲国产精品久久| 日韩高清亚洲日韩精品一区二区| 蜜芽久久人人超碰爱香蕉| 亚洲爆乳WWW无码专区| 午夜精品福利亚洲国产| 中文字幕有码日韩精品| 日韩乱码人妻无码中文字幕视频| 日产国产一区二区不卡| 久久精品不卡一区二区| 色香欲天天影视综合网| 成人免费乱码大片a毛片| 羞羞影院午夜男女爽爽免费视频| 国内精品无码一区二区三区| 欧美牲交a欧美牲交aⅴ图片 | 亚洲精品免费一二三区| 国产目拍亚洲精品二区| 国产精品一区在线蜜臀| 日本一区不卡高清更新二区| 中文字幕永久精品国产| 色狠狠色婷婷丁香五月| 久久天天躁狠狠躁夜夜婷| 精品一区二区亚洲国产| 99国产欧美另类久久久精品| 亚洲V天堂V手机在线| 精品视频在线观看免费观看| 午夜通通国产精品福利| 韩国无码AV片午夜福利| 中文字幕av无码不卡| 色猫咪av在线网址| 白嫩少妇无套内谢视频| 韩国免费a级毛片久久| 国产中文字幕精品免费| 无码日韩精品一区二区三区免费| 中国女人熟毛茸茸A毛片| 色狠狠色婷婷丁香五月|