        人血小板活化因子(PAF)英文說明書

        2013年04月02日 09:17:50人氣:400來源:上海科鑒生物科技有限公司

        資料類型jpg文件資料大小3125983
        下載次數89資料圖片 【點擊查看】
        上 傳 人上海科鑒生物科技有限公司 需要積分0
        關 鍵 詞人血小板,英文說明書,(PAF),活化因子
        【資料簡介】

        Human PAF

         
        FOR RESEARCH USE ONLY
         
        Assay range0.6ng/L - 20ng/L                96determinations
        Purpose
        This kit allows for the determination of PAF concentrations in Humanserum, cellculture supernates and other biological fluids
         
        Principle of the assay
        The kit assay Human PAFlevel in the sampleuse Purified Human PAFantibody to coat microtiter plate wells, make solid-phase antibody, then addPAFto wells,CombinedPAF antibody which With HRP labeled,become antibody - antigen - enzyme-antibody complex, after washing Compley,Add TMB substrate solution,TMB substrate becomes blue color At HRP enzyme-catalyzed,reaction is terminated by the addition of a sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450 nm. The concentration ofHuman PAFin the samples is then determined by comparing the O.D. of the samples to the standard curve.
        Materials provided with the kit

        1
        wash solution
        20ml×1bottle
        7
        Stopp Solution
        6ml×1 bottle
        2
        HRP-Conjugate reagent
        6ml×1 bottle
        8
        Standard40ng/L
        0.5ml×1 bottle
        3
        Microelisa stripplate
        12well×8strips
        9
        Standard diluent
        1.5ml×1bottle
        4
        Sample diluent
        6ml×1 bottle
        10
        Instruction
        1
        5
        Chromogen Solution A
        6ml×1 bottle
        11
        Closure plate membrane
        2
        6
        Chromogen Solution B
        6ml×1 bottle
        12
        Sealed bags
        1

        Specimen requirements
        1.       extractas soon as possible after Specimen collection,and according to the relevant literature, and should be experiment as soon as possible after the extraction. If it can’t, specimen can be kept in -20 ℃ to preserve, Avoid repeated freeze-thaw cycles.
        2.       Can’t detect the sample which contain NaN3, because NaN3 inhibits HRP active.
        Assay procedure
        1.       Dilute and add sample:Dilute Original density Standard as follow table:

        20ng/L
        5 Standard
        150μl Original density Standard+150μl Standard diluent
        10ng/L
        4 Standard
        150μl 5 Standard+150μl Standard diluent
        5ng/L
        3 Standard
        150μl 4 Standard+150μl Standard diluent
        2.5ng/L
        2 Standard
        150μl 3 Standard +150μl Standard diluent
        1.25ng/L
        1 Standard
        150μl 2 Standard +150μl Standard diluent

        2.add sampleSet blank wells separay (blank comparison wells don’t add sample and HRP-Conjugate reagent, other each step operation is same). testing sample well. add Sample dilution 40μl to testing sample well, then add testing sample 10μl (sample final dilution is 5-fold), add sample to wells , don’t touch the well wall as far as possible, and Gently mix.
        3.Incubate: After closing plate with Closure plate membrane ,incubate for 30 min at 37.
        4.Configurate liquid: 30-fold(or 20-fold) wash solution diluted 30-fold (or 20-fold) with distilled water and reserve.
        5.washingUncover Closure plate membrane, discardLiquid, dry by swing, add washing buffer to every well, still for 30s then drain,repeat 5 times, dry by pat.
        6.add enzymeAdd HRP-Conjugate reagent 50μl to each well, except  blank well.
        7.incubateOperation with 3.
        8.washingOperation with 5.
        9.colorAdd Chromogen Solution A 50ul and Chromogen Solution B to each well, evade the light preservation for 15 min at 37
        10.Stop the reactionAdd Stop Solution50μl to each well, Stop the reaction(the blue color change to yellow color).
        11.assaytake blank well as zero , Read absorbance at 450nm after Adding Stop Solution and within 15min.
        Steps description

        Standard, Sample diluent

         

        AddStandard, Sample diluent, incubate for 30 min at 37.

         

        Wash 5 time,AddHRP-Conjugate reagent, incubate for 30 min at 37.

         

        Wash 5 times,Add Chromogen Solution A and B, incubate for 30 min at 37.

         

        AddStopp Solution

         

        Read absorbance at 450nm within 15 min

         

        calculate

        Calculate
        Take the standard density as the horizontal, the OD value for the vertical ,draw the standard curve on graph paper, Find out the corresponding density according to the sample OD value by the Sample curve, multiplied by the dilution multiple, or calculate the straight line regression equation of the standard curve with the standard density and the OD value ,with the sample OD value in the equation, calculate the sample density, multiplied by the dilution factor, the result is the sample actual density.
        Important notes
        1.       The kit takes out from the refrigeration environment should be balanced 15-30 minutes in the room temperature, ELISA plates coated if has not use up after opened, the plate should be stored in Sealed bag.
        2.       washing buffer will Crystallization separation, it can be heated the water helps dissolve when dilute . Washing does not affect the result.
        3.       add Sample with sampler Each step, And proofread its accuracy frequently, avoids the experimental error. add sample within 5 min, if the number of sample is much , recommend to use Volley .
        4.       if the testing material content is excessively higher (The sample OD is bigger than the first standard well ),please dilute Sample (n-fold), Please diluenteand multiplied by the dilution factor.×n×5.
        5.       Closure plate membrane only limits the disposable use, to avoid cross-contamination.
        6.       The substrate evade the light preservation.
        7.       Please according to use instruction strictly, The test result determination must take the microtiter plate reader as a standard.
        8.       All samples, washing buffer and each kind of reject should according to infective material process.
        9.       Do not mix reagents with those from other lots.
         
        Storage and validity
        1Storage 2-8℃.
        2validity six months

        上海科鑒生物科技有限公司作者

        上一篇:防腐聚乙烯熱收縮帶補口溫度控制

        下一篇:聚乙烯熱收縮帶補口溫度控制方法


        我要投稿
        • 投稿請發送郵件至:(郵件標題請備注“投稿”)hbzhan@vip.qq.com
        • 聯系電話0571-87759680
        環保行業“互聯網+”服務平臺
        環保在線APP

        功能豐富 實時交流

        環保在線小程序

        訂閱獲取更多服務

        微信公眾號

        關注我們

        抖音

        環保在線網

        抖音號:hbzhan

        打開抖音 搜索頁掃一掃

        視頻號

        環保在線

        公眾號:環保在線

        打開微信掃碼關注視頻號

        快手

        環保在線

        快手ID:2537047074

        打開快手 掃一掃關注
        意見反饋
        主站蜘蛛池模板: 热99re99首页精品亚洲五月天| 国外欧美一区另类中文字幕| 午夜精品久久久久久久99热下载 | 中文国产成人精品久久不卡| 国产v精品成人免费视频71pao| 99精品热在线在线观看视| 爱做久久久久久| 亚洲天堂区| 中文字幕在线欧美| 91欧美亚洲国产五月天| 国产精品亚洲欧美日韩久久| 日韩乱码人妻无码中文字幕视频 | 四虎精品视频永久免费| 免费无码肉片在线观看| 久久久久免费看成人影片| 国产无人区码一区二区| 亚洲一区二区偷拍精品| 久久婷婷五月综合97色直播| 国产精品大全中文字幕| 国产精品天干天干综合网| 亚洲av日韩av永久无码电影| 国产一卡2卡三卡4卡免费网站| 国产亚洲精品VA片在线播放| 少妇高潮水多太爽了动态图| 日本亚洲成高清一区二区三区| 国产成人高清精品免费软件 | 波多野结衣在线一区二区| 亚洲日韩精品欧美中文字幕| 国产亚洲视频免费播放| 国产不卡一区二区四区| 国产精品av中文字幕| 91精品国产自产91精品资源| 国产欧美日韩va另类在线播放| 久久国产高清视频| 欧美激情一区二区三区成人 | 亚洲精品香蕉一区二区| 蜜桃视频一区二区三区| 美女无遮挡免费视频网站| 成人亚欧欧美激情在线观看| 亚洲综合精品第一页| 国产欧美综合在线观看第十页|