         Human Insulin-like Growth Factor 1(IGF-1)ELISA Kit
        Catalog No. CSB-E04580h
        (96 T)
        This immunoassay kit allows for the in vitro quantitative determination of human IGF-1 concentrations in serum, plasma .
        Expiration date six months from the date of manufacture
        FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC PROCEDURES.
         
        廈門慧嘉生物長期經(jīng)營ELISA試劑盒及抗體、細(xì)胞因子、生化試劑、耗材等生物試劑產(chǎn)品。誠信經(jīng)營,價(jià)格實(shí)惠,服務(wù)周到,質(zhì)量有保證。歡迎廣告老師來詢!:   :  1048735792 或登陸/download(下載原版說明書)
         
        PRINCIPLE OF THE ASSAY
        The microtiter plate provided in this kit has been pre-coated with an antibody specific to IGF-1. Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody preparation specific for IGF-1 and Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then a TMB (3,3',5,5' tetramethyl-benzidine) substrate solution is added to each well. Only those wells that contain IGF-1, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of a sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450 nm ± 2 nm. The concentration of IGF-1 in the samples is then determined by comparing the O.D. of the samples to the standard curve.
        DETECTION RANGE
        7.8 ng/ml-500ng/ml. The standard curve concentrations used for the ELISA’s were 500 ng/ml, 250 ng/ml, 125 ng/ml, 62.5 ng/ml,
        31.2 ng/ml, 15.6 ng/ml, 7.8 ng/ml.
        SPECIFICITY
        This assay recognizes human IGF-1. No significant
        cross-reactivity or interference was observed.
        SENSITIVITY
        The minimum detectable dose of human IGF-1 is typically less
        than 2 ng/ml.
        The sensitivity of this assay, or Lower Limit of Detection (LLD)
        was defined as the lowest protein concentration that could be
        differentiated from zero.
        MATERIALS PROVIDED
        Reagent Quantity
        Assay plate 1 Standard 2 Sample Diluent 1 x 20 ml Biotin-antibody Diluent 1 x 10 ml HRP-avidin Diluent 1 x 10 ml Biotin-antibody 1 x 120μl HRP-avidin 1 x 120μl
        1 x20 ml
        Wash Buffer
        (25×concentrate)
        TMB Substrate 1 x 10 ml
        Stop Solution 1 x 10 ml
        STORAGE
        1.    Unopened test kits should be stored at 2-8?C upon receipt and the microtiter plate should be kept in a sealed bag. The test kit may be used throughout the expiration date of the kit, provided it is stored as prescribed above. Refer to the package label for the expiration date.
        2.    Opened test plate should be stored at 2-8?C in the aluminum foil bag with desiccants to minimize exposure to damp air. The kits will remain stable until the expiring date shown, provided it is stored as prescribed above.
        3.    A microtiter plate reader with a bandwidth of 10 nm or less and an optical density range of 0-3 OD or greater at 450nm wavelength is acceptable for use in absorbance measurement.
         
        REAGENT PREPARATION
        Bring all reagents to room temperature before use.
        1         Wash Buffer If crystals have formed in the concentrate, warm up to room temperature and mix gently until the crystals have compley dissolved. Dilute 20 ml of Wash Buffer Concentrate into deionized or distilled water to prepare 500 ml of Wash Buffer.
        2         Standard Centrifuge the standard vial at 6000-10000rpm for 30s. Reconstitute the Standard with 1.0 ml of Sample Diluent. This reconstitution produces a stock solution of 500 ng/ml. Allow the standard to sit for a minimum of 15 minutes with gentle agitation prior to making serial dilutions. The undiluted standard serves as the high standard (500 ng/ml). The Sample Diluent serves as the zero standard (0 ng/ml). Prepare fresh for each assay. Use within 4 hours and discard after use.
        3         Biotin-antibody Centrifuge the vial before opening. Dilute to the working concentration using Biotin-antibody Diluent(1:100), respectively.
        4         HRP-avidin Centrifuge the vial before opening. Dilute to the working concentration using HRP-avidin Diluent(1:100), respectively.
         
        Precaution: The Stop Solution provided with this kit is an acid solution. Wear eye, hand, face, and clothing protection when using this material.
        OTHER SUPPLIES REQUIRED
        1          Microplate reader capable of measuring absorbance at 450 nm, with the correction wavelength set at 540 nm or 570 nm.
        2          Pipettes and pipette tips.
        3          Deionized or distilled water.
        4          Squirt bottle, manifold dispenser, or automated microplate washer.
        5          An incubator which can provide stable incubation conditions up to 37°C±0.5°C.
         
        SAMPLE COLLECTION AND STORAGE
        1          Serum Use a serum separator tube (SST) and allow samples to clot for 30 minutes before centrifugation for 15 minutes at 1000 g. Remove serum and assay immediay or aliquot and store samples at -20°C. Centrifuge the sample again after thawing before the assay. Avoid repeated freeze-thaw cycles.
        2          Plasma Collect plasma using citrate, EDTA, or heparin as an anticoagulant. Centrifuge for 15 minutes at 1000 g within 30 minutes of collection. Assay immediay or aliquot and store samples at -20°C. Centrifuge the sample again after thawing before the assay. Avoid repeated freeze-thaw cycles.
         
        Note: Grossly hemolyzed samples are not suitable for use in this assay.
        ASSAY PROCEDURE
        Bring all reagents and samples to room temperature before use. It is recommended that all samples, standards, and controls be assayed in duplicate. All the reagents should be added directly to the liquid level in the well. The pipette should avoid contacting the inner wall of the well.
        1         Add 100μl of Standard, Blank, or Sample per well. Cover with the adhesive strip. Incubate for 2 hours at 37°C.
        2         Remove the liquid of each well, don’t wash.
        3         Add 100μl of Biotin-antibody working solution to each well. Incubate for 1 hour at 37°C. Biotin-antibody working solution may appear cloudy. Warm up to room temperature and mix gently until solution appears uniform.
        4         Aspirate each well and wash, repeating the process three times for a total of three washes. Wash: Fill each well with
         
        Wash Buffer (200μl) and let it stand for 2 minutes, then
        remove the liquid by flicking the plate over a sink. The remaining drops are removed by patting the plate on a paper towel. Complete removal of liquid at each step is essential to good performance.
         
        1         Add 100μl of HRP-avidin working solution to each well. Cover the microtiter plate with a new adhesive strip. Incubate for 1 hour at 37°C.
        2         Repeat the aspiration and wash five times as step 4.
        3         Add 90μl of TMB Substrate to each well. Incubate for 10-30 minutes at 37°C. Keeping the plate away from drafts and other temperature fluctuations in the dark.
        4         Add 50μl of Stop Solution to each well when the first four wells containing the highest concentration of standards develop obvious blue color. If color change does not appear uniform, gently tap the plate to ensure thorough mixing.
        5         Determine the optical density of each well within 30 minutes, using a microplate reader set to 450 nm.
         
        CALCULATION OF RESULTS
        Using the professional soft "Curve Exert 1.3" to make a standard curve is recommended, which can be downloaded from our web.
        Average the duplicate readings for each standard, control, and sample and subtract the average zero standard optical density. Create a standard curve by reducing the data using computer software capable of generating a four parameter logistic (4-PL) curve-fit. As an alternative, construct a standard curve by plotting the mean absorbance for each standard on the x-axis against the concentration on the y-axis and draw a best fit curve through the points on the graph. The data may be linearized by plotting the log of the IGF-1 concentrations versus the log of the O.D. and the best fit line can be determined by regression analysis. This procedure will produce an adequate but less precise fit of the data. If samples have been diluted, the concentration read from the standard curve must be multiplied by the dilution factor.
        LIMITATIONS OF THE PROCEDURE
        1          The kit should not be used beyond the expiration date on the kit label.
        2          Do not mix or substitute reagents with those from other lots or sources.
        3          It is important that the Standard Diluent selected for the standard curve be consistent with the samples being assayed.
        4          If samples generate values higher than the highest standard, dilute the samples with the appropriate Standard Diluent and repeat the assay.
        5          Any variation in Standard Diluent, operator, pipetting technique, washing technique, incubation time or temperature, and kit age can cause variation in binding.
        6          This assay is designed to eliminate interference by soluble receptors, binding proteins, and other factors present in biological samples. Until all factors have been tested in the Immunoassay, the possibility of interference cannot be excluded.
         
        TECHNICAL HINTS
        1          Centrifuge vials before opening to collect contents.
        2          When mixing or reconstituting protein solutions, always avoid foaming.
        3          To avoid cross-contamination, change pipette tips between additions of each standard level, between sample additions, and between reagent additions. Also, use separate reservoirs for each reagent.
        4          When using an automated plate washer, adding a 30 second soak period following the addition of wash buffer, and/or rotating the plate 180 degrees between wash steps may improve assay precision.
        5          To ensure accurate results, proper adhesion of plate sealers during incubation steps is necessary.
        6          Substrate Solution should remain colorless or light blue until added to the plate. Keep Substrate Solution protected from light. Substrate Solution should change from colorless or light blue to gradations of blue.
        7          Stop Solution should be added to the plate in the same order as the Substrate Solution. The color developed in the wells will turn from blue to yellow upon addition of the Stop Solution. Wells that are green in color indicate that the Stop Solution has not mixed thoroughly with the Substrate Solution.

        廈門慧嘉生物科技有限公司作者

        上一篇:豚鼠白介素受體拮抗劑(ILRa)酶聯(lián)免疫(Elisa)

        下一篇:內(nèi)皮素-(ET-)ELISA試劑盒說明


        我要投稿
        • 投稿請發(fā)送郵件至:(郵件標(biāo)題請備注“投稿”)hbzhan@vip.qq.com
        • 聯(lián)系電話0571-87759680
        環(huán)保行業(yè)“互聯(lián)網(wǎng)+”服務(wù)平臺(tái)
        環(huán)保在線APP

        功能豐富 實(shí)時(shí)交流

        環(huán)保在線小程序

        訂閱獲取更多服務(wù)

        微信公眾號(hào)

        關(guān)注我們

        抖音

        環(huán)保在線網(wǎng)

        抖音號(hào):hbzhan

        打開抖音 搜索頁掃一掃

        視頻號(hào)

        環(huán)保在線

        公眾號(hào):環(huán)保在線

        打開微信掃碼關(guān)注視頻號(hào)

        快手

        環(huán)保在線

        快手ID:2537047074

        打開快手 掃一掃關(guān)注
        意見反饋
        主站蜘蛛池模板: 国产精品福利中文字幕| 国产成人精品视频不卡| 性奴sm虐辱暴力视频网站| 国产日韩精品中文字幕| 亚洲精品国产一二三区| 久久精品一本到99热免费| 在线精品国产中文字幕| 日本高清在线观看WWW色| 欧美大胆老熟妇乱子伦视频| 人妻少妇偷人一区二区| 国产成人午夜精品福利| 99久久精品费精品国产一区二| 白丝乳交内射一二三区| 亚洲成人资源在线观看| 国产精品自在拍首页视频8| 国产午夜福利视频在线| 亚洲精品综合网二三区| 2019久久久高清日本道| 国产成人8X人网站视频| 亚洲精品一区二区制服| 国产另类ts人妖一区二区| av在线播放国产一区| 最近中文字幕国产精选| 极品少妇无套内射视频| 一本一道av无码中文字幕麻豆| 不卡国产一区二区三区| 中文字幕av无码不卡| 亚洲欧洲精品日韩av| 嗯灬啊灬把腿张开灬动态图| 性奴sm虐辱暴力视频网站| 在线播放亚洲成人av| 99久久无码私人网站| 国产午夜亚洲精品国产成人| 日本欧美一区二区三区在线播放 | 天堂V亚洲国产V第一次| 无码人妻aⅴ一区二区三区蜜桃| 少妇xxxxx性开放| 99久久99这里只有免费费精品 | 国产美女高潮流白浆视频| 无码囯产精品一区二区免费| 午夜福利片1000无码免费|